Front Panel Components |
|
| BNC Output Connector: |
RF output, 50 Ohm source, 500 mVrms Max. (carrier level) into 50 Ohms; adjustable in 1 dB steps. |
| Output Attenuator: | Adjustable in 1 dB steps from 0 dB to 63 dB attenuation. |
| BNC SYNC Connector: | TTL level sync. Negative transition synchronous with start of pattern. |
f0, +-f1, --f1, +-f2, --f2 Select Switch: |
Selects carrier frequency:
| f0 | = 450 kHz +5 Hz |
| +-f1 | = f0 + 250 Hz |
| --f1 | = f0 - 250 Hz |
| Optional +-f2 | = f0 + 2 kHz |
| Optional --f2 | = f0 - 2 kHz |
(Other -f values available on special order) |
| Pattern Select Switch: | Selects one of 15 modulation patterns. Standard patterns (Pattern Bank 1):
| (1) L+R 25% | (9) L-R 100% |
| (2) L+R 50% | (10) L 25% |
| (3) L+R 75% | (11) L 50% |
| (4) L+R 100% | (12) L 75% |
| (5) L+R 95% | (13) R 25% |
| (6) L+R +125%, -100% | (14) R 50% |
| (7) L-R 50% | (15) R 75% |
| (8) L-R 90% | (16) 7 TONES |
(Customer specified patterns on special order) |
| Pattern Bank Switch: | Enables optional second memory board with 16 additional modulation patterns. |
| Modulation Frequency Switch: | Selects modulation frequencies of 62.5, 125, 250, 500 Hz, 1, 2, 4, 8 kHz. (C-QUAM spectra most accurate .5-2 kHz.) |
| Pilot Select Switch: | This four position rotary switch selects no pilot (O position) or
a 25 Hz pilot tone with one of the following levels:
4% pilot(x ±2.29º), 5% pilot (x ±2.86º), or 6% pilot (x ±3.43º) |
| Pulse/Carrier Switch: | This is a three position toggle switch. Switch "down" selects the unmodulated carrier. Switch at "center" selects the modulation pattern in accordance with the Pattern Select Switch setting. Switch "up" selects pulse pattern at 64 cycles of selected modulation and approximately one second unmodulated carrier. |
| Co-Channel Switch: | This is a two position toggle switch. Switch "up" phase modulates ±5º at 6 Hz the carrier or the pattern established by the
Pattern Select Switch setting. Switch "down" turns off the phase modulation. |
| Power Switch: | This alternate action pushbutton switch controls the application of AC power. When AC power is applied, the switch is illuminated. |
Rear Panel Components |
|
| AC Cord Connector: | 120/240 VAC, 50/60 Hz. |
| Local/Remote Jumper: | When jumper is in place, front panel controls function as described. When jumper is removed, front panel controls are not functional and remote connector is enabled. |
| Remote Connector: | 37 pin "D" connector (mating connector supplied) for TTL compatible, transistor pulldown, or dry contact remote control of all functions described above except AC power. |